Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Rev. otorrinolaringol. cir. cabeza cuello ; 76(1): 15-20, abr. 2016. ilus
Article in Spanish | LILACS | ID: lil-784878

ABSTRACT

Introducción: La prevalencia de hipoacusia infantil aumenta con la edad, ya que se agregan hipoacusia de conducción y sensorioneurales de inicio tardío, estimándose en hasta 9%. Objetivo: Determinar la prevalencia de hipoacusia en una muestra de escolares. Material y método: Estudio de corte transversal. Se consideraron cuatro escuelas de la comuna de San Bernardo y dos de Lo Espejo. Resultados: Fueron incluidos 196 escolares. La edad promedio fue 9,5 años. Fueron evaluadas 106 mujeres (54%) y 90 hombres (46%). Se observaron 11 casos (5,6%) de hipoacusia leve en oído derecho, y 9 casos (4,52%) de hipoacusia en oído izquierdo (8 leves, y 1 moderada). Seis casos fueron de hipoacusia bilateral, 5 de hipoacusia unilateral en oído derecho, y 3 de hipoacusia unilateral en oído izquierdo. Todas fueron de tipo conductiva. Las causas de hipoacusia fueron otitis media con efusión, tapón de cerumen, y otitis media crónica. Hubo un caso de agenesia de conducto auditivo. Conclusiones: La hipoacusia es una condición frecuente en etapa escolar, siendo principalmente conductiva. La prevalencia se encuentra dentro de lo esperado. Debido a las consecuencias asociadas a la hipoacusia en esta etapa, es importante implementar un programa de tamizaje auditivo en escolares en nuestro país.


Introduction: The prevalence of hearing loss in childhood increases with age, as conductive hearing loss or late onset sensorineural hearing lossare added, estimated at up to 9%. Aim: To determine the prevalence of hearing loss in a school sample. Material and method: Cross sectional study. 4 schools of San Bernardo and 2 of Lo Espejo were included. Results: We included 196 children. Mean age was 9.5 years. We evaluated 106 women (54%) and 90 men (46%). 11 cases (5.6%) of mild hearing loss in the right ear, and 9 cases (4.52%) of hearing loss in the left ear (8 in mild range, and 1 in moderate range) were observed. Six cases were bilateral hearing loss, unilateral hearing loss 5 in the right ear, and 3 of unilateral hearing loss in the left ear. All were conductive type. Causes of hearing loss wereotitis media with effusion, earwax, and chronic otitis media. There was 1 case of agenesis of the ear canal. Conclusion: Hearing loss is a common condition in school children, being primarily conductive. The prevalence is within expected. Beause of the consecuences of the hearing loss in this age group, it is important to implement a hearing screening program in schools in our country.


Subject(s)
Humans , Male , Female , Child , Hearing Loss/etiology , Hearing Loss/epidemiology , Chile , Mass Screening , Prevalence , Cross-Sectional Studies
2.
Rev. otorrinolaringol. cir. cabeza cuello ; 75(2): 89-95, ago. 2015. tab
Article in Spanish | LILACS | ID: lil-757889

ABSTRACT

Introducción: La hipoacusia es una condición prevalente que tiene consecuencias en el desarrollo de los individuos. Cada vez cobran mayor importancia los programas de tamizaje de hipoacusia. Una estrategia involucra la utilización de cuestionarios de tamizaje de hipoacusia. Objetivos: Realizar la adaptación transcultural al español de los instrumentos de tamizaje auditivos ABEL y TEAP. Material y método: Se realizó un estudio de corte transversal de validación de cuestionario en escolares de cuarto básico. Se utilizó la teoría clásica de tests, que incluye validez de criterio, confiabilidad test-retest y consistencia interna. Resultados: Fueron evaluados 100 escolares de San Bernardo. Cincuenta y dos por ciento de la muestra fueron mujeres. El promedio (DE) de edad fue 9,75 (± 0,78) años. Hubo tres casos de hipoacusia bilateral y dos de hipoacusia unilateral. La consistencia interna del test ABEL fue de 0,73. La consistencia interna del test TEAP fue de 0,82. La confiabilidad test-retest del ABEL fue 0,86 y del TEAP fue 0,86. No hubo diferencia entre los puntajes del ABEL ni del TEAP entre niños con hipoacusia y sin hipoacusia. Conclusión: Sería de utilidad utilizar cuestionarios para el tamizaje de hipoacusia en escolares. Estos resultados permiten plantear un programa formal de tamizaje basado en cuestionarios de hipoacusia.


Introduction: Hearinglossis a prevalent condition that has consequences for children's development. As a result, screening programs for hearing loss are of increasing importance. One screening strategy involves the use of questionnaires for people with hearing loss. Aim: Transcultural adaptation to Spanish of the hearing screening in struments ABEL and the TEAP. Material and method: A cross-sectional questionnaire validation study in fourth grade school children was conducted. Classical test theory, including criterion validity, test-retest reliability and internal consistency was used. Results: A total of 100 school children in San Bernardo were evaluated. 52% of the sample were girls. The mean (SD) age was 9.75 (± 0.78) years. There were three cases of bilateral hearing loss and two cases of unilateral hearing loss. The internal consistency of the test was 0.73 for ABEL. The internal consistency was 0.82 for TEAP. The test-retest reliability was 0.86 for ABEL and for TEAP was 0.86. There was no difference between the scores of ABEL or TEAP between the children with hearing loss and those without hearing loss. Conclusions: It would be helpful to use questionnaires to screen for hearing loss in school. These results support a formal screening program based on questionnaires of hearing loss.


Subject(s)
Humans , Male , Female , Child , Mass Screening , Surveys and Questionnaires , Hearing Loss/epidemiology , Translations , Chile , Cross-Sectional Studies , Reproducibility of Results
3.
Rev. otorrinolaringol. cir. cabeza cuello ; 74(2): 161-166, 2014. ilus
Article in Spanish | LILACS | ID: lil-726168

ABSTRACT

La atresia de conducto auditivo externo tiene una incidencia de 1 por 1.000 ó 2.000 nacidos vivos, predominantemente unilateral. Su manejo actual es controversial, en especial la cirugía de reconstrucción. En el último tiempo se han desarrollado dispositivos osteointegrados, que han revolucionado el tratamiento y cuestionado la indicación de cirugía. El liderazgo por un tiempo importante lo ha tenido el dispositivo tipo BAHA, pero que ha tenido problemas en el largo plazo, principalmente en relación con el tornillo del implante. En respuesta a estos problemas, se ha diseñado un nuevo implante osteointegrado de nombre Bonebridge®, con beneficios frente a su antecesor. Como en nuestro medio se tiene poca experiencia en este dispositivo se presenta una revisión a propósito de un caso clínico exitoso. El caso corresponde a un paciente de 18 años con hipoacusia de conducción máxima bilateral congénita, con diagnóstico de atresia de conducto auditivo externo bilateral, con inadecuada ganancia auditiva del cintillo óseo tradicional. Tanto la revisión bibliográfica como el caso clínico nos permiten aseverar que Bonebridge® corresponde a tratamiento adecuado en el manejo de la atresia del conducto auditivo externo, con ciertos beneficios sobre otros dispositivos y la cirugía.


The external auditory canal atresia has an incidence of 1 per 1000 or 2000 live births predominantly unilateral. Its management is controversial, especially with the decision of reconstructive surgery. Lately, have developed osseo integrated bone conduction devices, which have come to revolutionize the treatment and questioning the indication for surgery. The leadership for a long time its has had it the BAHA device type, but has several problems in long-term, mainly in relation to the screw used in the implant. In response to this problems, was designed a new osseo integrated implant named Bonebridge®, showing benefits over its predecessor. As in our setting there is little experience with this device, we present a review about a successful clinical case. The case is a patient of 18 years with a maximal bilateral hearing loss caused by a congenital bilateral atresia of the external auditory canal, and inadequate audition gain with traditional bone headband. As much the bibliographical overhaul as the clinical case allows to assert that Bone-bridge® corresponds to an alternative of treatment in the atresia of the external auditory canal and with certain benefits by on the other devices, as the surgery.


Subject(s)
Humans , Male , Adolescent , Prostheses and Implants , Bone Conduction , Ear Canal/abnormalities , Hearing Loss, Conductive/surgery , Hearing Loss, Conductive/etiology